Specifications

Model
STL-PHT60P; STL-PHT110P; STL-PHT130P; STL-PHT160P; STL-PHT180P; STL-PHT200P; STL-PHT300P; STL-PHT400P;
Door Type
Automatic door vertical
Electric Heating
Electric heating
Working Temperature
50±3 ℃

Full specification sheet

  • Model [STL-PHT60P]: STL-PHT60P
  • Model [STL-PHT110P]: STL-PHT110P
  • Model [STL-PHT130P]: STL-PHT130P
  • Model [STL-PHT160P]: STL-PHT160P
  • Model [STL-PHT180P]: STL-PHT180P
  • Model [STL-PHT200P]: STL-PHT200P
  • Model [STL-PHT300P]: STL-PHT300P
  • Model [STL-PHT400P]: STL-PHT400P
  • Capacity (L) [STL-PHT60P]: 60
  • Capacity (L) [STL-PHT110P]: 110
  • Capacity (L) [STL-PHT130P]: 130
  • Capacity (L) [STL-PHT160P]: 160
  • Capacity (L) [STL-PHT180P]: 180
  • Capacity (L) [STL-PHT200P]: 200
  • Capacity (L) [STL-PHT300P]: 300
  • Capacity (L) [STL-PHT400P]: 400
  • Door Type: Automatic door vertical
  • Electric Heating: Electric heating
  • Working Temperature: 50±3°C
  • Hydrogen Peroxide Concentration: 58% (Standard);
  • Hydrogen Peroxide Concentration: Hydrogen peroxide purification technology, 95%±5% (optional);
  • Hydrogen Peroxide Cartridge: Each cartridge contains 12 individual capsules. Single H₂O₂ dosage error: ≤ ±1%; pH value: ≤ 2.6 (acidic)
  • Total Cycle Time: Rapid sterilization time ≤ 45 min;
  • Total Cycle Time: Standard sterilization time ≤ 65 min;
  • Total Cycle Time: Enhanced sterilization time ≤ 85 min.
  • Power Supply [UNVERIFIED — 2 values, 8 models, check manually]: AC 220/110 V, 50/60 Hz | AC 380/220 V, 50/60 Hz (three-phase)
  • Consumption (kW) [STL-PHT60P]: 2.2
  • Consumption (kW) [STL-PHT110P]: 2.8
  • Consumption (kW) [STL-PHT130P]: 3.8
  • Consumption (kW) [STL-PHT160P]: 4
  • Consumption (kW) [STL-PHT180P]: 4.2
  • Consumption (kW) [STL-PHT200P]: 4.6
  • Consumption (kW) [STL-PHT300P]: 4.8
  • Consumption (kW) [STL-PHT400P]: 5
  • Chamber Size (W×D×H)(mm) [STL-PHT60P]: 620×350×280
  • Chamber Size (W×D×H)(mm) [STL-PHT110P]: 610×480×380
  • Chamber Size (W×D×H)(mm) [STL-PHT130P]: 710×480×380
  • Chamber Size (W×D×H)(mm) [STL-PHT160P]: 770×460×460
  • Chamber Size (W×D×H)(mm) [STL-PHT180P]: 860×460×460
  • Chamber Size (W×D×H)(mm) [STL-PHT200P]: 960×460×460
  • Chamber Size (W×D×H)(mm) [STL-PHT300P]: 960×560×560
  • Chamber Size (W×D×H)(mm) [STL-PHT400P]: 1010×660×600
  • External Size (W×D×H)(mm) [STL-PHT60P]: 770×660×1400
  • External Size (W×D×H)(mm) [STL-PHT110P]: 760×790×1600
  • External Size (W×D×H)(mm) [STL-PHT130P]: 860×790×1600
  • External Size (W×D×H)(mm) [STL-PHT160P]: 920×770×1760
  • External Size (W×D×H)(mm) [STL-PHT180P]: 1010×770×1760
  • External Size (W×D×H)(mm) [STL-PHT200P]: 1110×770×1760
  • External Size (W×D×H)(mm) [STL-PHT300P]: 1110×870×1960
  • External Size (W×D×H)(mm) [STL-PHT400P]: 1160×1165×1950
  • Shipping Size (W×D×H)(mm) [STL-PHT60P]: 970×830×1720
  • Shipping Size (W×D×H)(mm) [STL-PHT110P]: 960×890×1800
  • Shipping Size (W×D×H)(mm) [STL-PHT130P]: 970×890×1800
  • Shipping Size (W×D×H)(mm) [STL-PHT160P]: 1140×990×1960
  • Shipping Size (W×D×H)(mm) [STL-PHT180P]: 1230×990×1960
  • Shipping Size (W×D×H)(mm) [STL-PHT200P]: 1230×990×1960
  • Shipping Size (W×D×H)(mm) [STL-PHT300P]: 1300×1070×2260
  • Shipping Size (W×D×H)(mm) [STL-PHT400P]: 1380×1385×2150
  • N.W./G.W. (kg) [STL-PHT60P]: 233/263
  • N.W./G.W. (kg) [STL-PHT110P]: 295/335
  • N.W./G.W. (kg) [STL-PHT130P]: 300/340
  • N.W./G.W. (kg) [STL-PHT160P]: 320/365
  • N.W./G.W. (kg) [STL-PHT180P]: 340/385
  • N.W./G.W. (kg) [STL-PHT200P]: 360/400
  • N.W./G.W. (kg) [STL-PHT300P]: 396/456
  • N.W./G.W. (kg) [STL-PHT400P]: 500/560